The plev_options type exposes the following members.

Constructors

  NameDescription
Public methodplev_options

Fields

  NameDescription
Public fieldmax_diameter_only
Only return the maximum trim when selecting a pump. (Also called "max wheel," or "top curve".)
Public fieldoptimize_impeller_to_motor_power
After sizing the impeller trim and motor to the design point, increase the trim as much as possible (within pump limits) so that it takes full advantage of the configured motor's power rating.
Public fieldoverspeed_percentage
Allows PUMP-FLO to adjust the selected pump above test speed by the indicated percentage when determining whether or not to include the pump in the results. Normally, we do not increase pump speed as part of selection.
Public fieldspeed_adjusted_search
Allows PUMP-FLO to decrease the speed of the selected pump to meet the indicated design point. Normally, we only trim and do not speed adjust during pump selection. Speed adjustment always happens after trimming to minimize the necessary adjustment.
Public fieldspeed_adjusted_search_percentage
Amount of total allowable adjustment when speed_adjusted_search is turned on. Does not affect adjustments going above the test speed, only those that are below.

See Also